Military Application Resilience
Emulating real-world network conditions to verify applications & systems
Designed for high-speed Ethernet fabrics and AI data center interconnects, Calnex SNE Ignite 400G sits inline with traffic and introduces network latency in a controlled, precise, and repeatable way, with one-nanosecond granularity.
It supports 100% line-rate traffic with zero-loss packet forwarding and ultra-low intrinsic latency, enabling accurate validation against the demanding performance requirements of AI fabric environments.
To achieve the extreme efficiency it is designed for, reliable RDMA transport over Ethernet, such as RoCEv2 with Data Center Quantized Congestion Notification (DCQCN) and Ultra Ethernet Transport (UET), depends on rigorously tested and optimized flow control, timeout, and retransmission logic.
Ignite 400G enables test engineers to validate RoCEv2 and UET performance and reliability in the lab, under real-world accurate latency. With no network stack in the path, Ignite 400G preserves header integrity, supporting accurate timeout, retransmission and protocol behavio=r analysis.
Ignite 400G provides a transparent path for Priority Flow Control (PFC) and congestion signaling. By not intercepting or terminating MAC control frames, it enables accurate tuning of Transmit on/Transmit off (XON/XOFF) thresholds and validation of stop-and-go flow-control behavior under realistic propagation delay.
This allows engineers to observe how buffer management responds to the amount of data in flight, without the test system itself introducing unintended flow-control behavior.
In DCQCN-based RoCEv2 networks, PFC and ECN should be tuned to work as a coordinated sequence, not as competing control mechanisms. ECN should act first, with marking thresholds set low enough that congestion is signalled and the sender starts reducing rate before the queue grows into the PFC XOFF region.
PFC, with enough buffer headroom to absorb packets already in flight, should only be used as safety brake for sharp bursts, incast events, or cases where ECN feedback arrives too late. The critical design point is the margin between ECN marking and PFC activation under real traffic and delay conditions.
Ignite 400G helps test that margin by stressing the ECN/CNP and PFC control loops. This shows whether ECN can stabilise the queue before PFC fires, whether PFC prevents loss when it does fire, and whether poor settings lead to excessive pause, throughput oscillation, or complete degradation.
Ignite 400G can introduce up to 250ms of latency, emulating the propagation delay of distances up to 25,000 kilometers while avoiding the PHY effects, practical constraints, and limitations of fiber spools.
As data centers and AI clusters continue to expand in physical scale, Ignite 400G enables engineers to validate that the network responds predictably and optimally under extended-distance conditions.
CALNEX Ignite 400G